Power supply

Low-voltage main distribution board, feed-in

A safe power supply forms the basis for secure data

Einspeisung Rechenzentrum

Safety, maximum availability and economic viability in server parks, data centres and IT rooms are now a MUST and require a fault-free power supply. The supplied medium voltage is transformed down to 400 V in the transformer stations and fed to the data centre via cable bars or busbars and the low-voltage main distribution board and normal system sub-distribution panel. The normal system sub-distribution panel also provides the uninterruptible power supply (UPS) with electricity. The power supply is permanently monitored by Bender AC/DC sensitive and multi-channel residual current monitoring systems. This avoids fire hazards, operational interruptions, functional problems damage and, in the worst-case scenario, data loss as a result of faulty electrical insulation or EMC influence. Bender monitoring systems protect your data every day. Possible risks are recognised early before problems arise. Power quality is the perfect solution for monitoring of low-voltage main distribution boards. Monitoring of the central earthing points via an RCMS guarantees that there is only one connection between N and PE in line with the standards.


Downloads:

PDF Download Symbol Product overview ISOMETER®
PDF Download Symbol Product overview Power Quality
PDF Download Symbol Flyer Power Quality
PDF Download Symbol Specialist article The future needs safety

Products:

Insulation monitoring

Power Quality

Residual current monitoring

Coupling devices


Standards:

  • DIN VDE 0100-731
  • ETSI EN 301605

Sub-distribution panel, busbar systems

Interference-free and easy connection

Unterverteilung, Stromschienensysteme

The connection between the low-voltage main distribution board and the sub-distribution panels is via busbar systems in order to guarantee the supply is as fault-free as possible. Power quality and RCMS residual current monitoring systems help with this monitoring.

Products:

Residual current monitoring

Power Quality

Generators

Emergency power systems ensure uninterrupted power supply

Generator

Electricity providers are not always able to guarantee perfect supply of electrical energies everywhere. Short interruptions or sustained power outages must be bridged by emergency power systems in order to maintain the operation of a data centre, including the associated technical systems, such as air-conditioning, electricity and security. The Bender solutions control the changeover and monitor the emergency power system for electrical faults.


Downloads:

PDF Download Symbol Product overview Residual Current Monitoring
PDF Download Symbol Product overview Power Quality
PDF Download Symbol Market segment brochure Data centre
PDF Download Symbol Specialist article Construction of a new computer centre

Products:

Insulation monitoring

Coupling devices


Standards:

  • DIN VDE 0100-731
  • ETSI EN 301605

UPS

Switching to emergency power without interruption

USV im Rechenzentrum

An uninterruptible power supply (UPS) is used to ensure the supply of critical electrical loads in the event of problems in the power supply. The UPS systems (normally battery or oscillating weight systems) bridge the period until the emergency power systems (generators) are activated or the system is available again. Electrical safety is continuously monitored by Bender products. 


Downloads:

PDF Download Symbol Product overview Residual Current Monitoring
PDF Download Symbol Product overview Power Quality
PDF Download Symbol Market segment brochure Data centre
PDF Download Symbol Specialist article Bender protects high-availability building installations

Products:

Insulation monitoring

Residual current monitoring

Measuring current transformers


Standards:

  • DIN EN 50272-2