Buildings

Railway stations

Safe building technology for satisfied customers

Bahnhof

The railway station itself is now a building with a variety of uses. It is not only where the train is loaded and unloaded, it also accommodates a considerable service centre including supermarkets, restaurants and many other shops. These are all fed centrally from the main distribution board and should also continue to function if there is an electrical fault in one small part of the system. This can be perfectly achieved using an RCMS residual current measurement system. This means faults are detected long before a normal fault current circuit breaker would trip. This increases the availability of the system as a whole and thus significantly improves the satisfaction of both tenants and passengers. The RCMS also improves and simplifies maintenance and troubleshooting.


Downloads:

PDF Download Symbol Product overview Residual Current Monitoring
PDF Download Symbol Product overview Power Quality
PDF Download Symbol Flyer Power Quality
PDF Download Symbol Specialist article Fault location within a shorter space of time

Products:


Residual current monitoring

Power Quality


Standards:

  • DIN EN 50172

Depots

Electrical safety for repair and maintenance

Werkstatthalle

A service depot for the repair and maintenance of railway vehicles requires and services all current drives for locomotives and carriages and also external lifting and transport equipment. This should still work when there is an electrical fault. Faults are detected by an RCMS residual current monitoring system before a normal fault current circuit breaker would trip. This increases the availability of the system as a whole and significantly accelerates maintenance and troubleshooting. Unearthed power supplies are monitored via insulation monitoring devices to check the condition of the insulation. Faulty outgoing circuits of the power supply can be identified using insulation fault location systems.


Downloads:

PDF Download Symbol Product overview ISOMETER®
PDF Download Symbol Specialist article Fault location within a shorter space of time

Products:


Residual current monitoring

Power Quality

Insulation monitoring


Standards:

  • EN 61557-8
  • EN 61557-9
  • EN 61557-15

Tunnels

Safe power supply even in the event of catastrophes

Tunnel

Railways in mountainous areas run over a series of tunnels and bridges. The operators of the routes must be prepared for a train accident in a tunnel. Valuable time is often lost before rescue trains reach the scene of the accident. Therefore, new stretches are fitted with fire stations and technical emergency services along the route for disaster relief. In order to round off the rescue system, there are hydrants and electrical panels installed in the tunnels. This gives the emergency services quick access to sufficient quantities of water and electrical energy. The power supply is essentially executed as an IT system.


Downloads:

PDF Download Symbol Product overview ISOMETER®
PDF Download Symbol Specialist article Insulation fault location - Planning and set up

Products:

Insulation monitoring

Insulation fault location

 

Standards:

  • EN 61557-8
  • EN 61557-9
Bender. The Power in Electrical Safety.©Trade terms | Data Protection Declaration | Imprint | Contact

© Bender GmbH & Co. KGTel. +49 6401 807-0